They are cheap and have a poor record over the last ten years with their COMBI`S. Ideal Classic 40NF. The problem occurs when dirt and carbon build up on the ignition and flame sensor probes, and the boiler must be stripped down so these can be cleaned. But - no hot water and no heating! ... Best new boiler - Replace Ideal Classic RS40 1995: Ideal Classic FF250....How do you drain the system? The boiler kicks in every 7-10mins even though water and heating are off. We’ve had an Ideal mini boiler for about 7 years. Remember, unless you’re dealing with low pressure or a faulty condensate, it’s best to call in an expert. Ideal boiler parts are also covered by our parts accreditation scheme – meaning you can get exactly the Ideal boiler spares you need, when you need them – all at your local Wolseley branch. Ideal Classic 280FF. 5. M. Hi, I have an Ideal logic 18 boiler that has today decided not to fire up. Landlords: Service vs Maintenance Contracts [What You’re Actually Paying For], Worcester Boiler Service Costs: A Detailed Guide. Ideal Classic 30NF. The Fix: Replace the ignition leads and the flame sensor, before adjusting the gas valve and fan speed as per the manufacturer’s instructions. 3 years old. Can anybody please advise on a fix. However its now developed a rather annoying tendency to have temperature fluctuations from the shower & hot water. No fault codes are show and pressure is fine. This boiler is not fit for purpose …four years old and this is happening. Had the same issue, it’s a blockage without a doubt, trap isn’t draining down condensate. I have to say I cannot really fault their after sales service. it drove me mad, 4 head scratching corgi engineer visits later, my mate came round and found the fault, he cleaned out the trap (this is standard practice), swilled out the outlet pipe by squirting warm water into it then (pipe that goes up into the boiler) then letting it drain out all the metal deposits (repeated several times until water was clear coming out), he then got a piece of garden hose about a foot long, popped in the end of the condensate pipe which flows down to the sink / drain, squirted another litre of warm water down the other end of the hose (sports cap bottle does the job nicely) did this for about 5 minutes, each time giving it 2 or 3 almighty blows whilst the water was trickling down, cleared the blockage. Thats a shame Susie, I am concerned about after costs with any boiler. For another 7 years later every service I insisted the engineer did this, never had a problem again till the day I sold the house. I have any Ideal Isar boiler and it shows LF flashing. I only had Idea boiler for 6 month since then has being give me problems water pressure keep drop down special in the morning.The idea engineer has come out today and told me that you got a system leak in radiators or pipe, got another contractor to find a leak he told me there is NO leak at all, I really need help to solve this problems. Any advice. Would this (most likely) be a programmer fault (part #35) or something else? My insurance sent a gas engineer round to fix my Ideal Isar boiler. When my ideal logic boiler which was fitted oct 2015 it was all fine but now when on central heating mode it makes an intermitant high pitched noise which stops when you run a hot tap. I have decided now to get boiler cover with the AA. Brand: Ideal Domestic Range: Classic Model: FF 260 GC Number: 41-387-04. With heating and water set to ‘off’ the boiler fires up all day sometimes with the pilot light being ignited sometimes not but in each case my smart meter display unit shows that gas is being used. When the display isn’t working the boiler still functions ok and I can control the central heating via the thermostat. Please advice ?? This is why we give the book compilations in this website. It covers just the boiler and all fittings within it. the sumps crack all the time causing products of combustion to spill into the house. 2 Classic Slimline FF - User's To light the boiler.Refer to Frame 1 1. Ideal Classic NF70. CHECK THAT THE ELECTRICITY SUPPLY TO THE BOILER IS OFF. however i can hear water from boiler overflow .redirected over flow into a drum ,and it is overflowing 13 litres per week. Ideal Classic FF250 Fault. It stays alight for about 2-3 mins and then turns off. There must be a blockage into the soil stack as I said its internal which I will investigate but I was very grateful for the post as it we just getting ready to go out and it’s now running fine with the water dripping into the bucket .. What does it mean when your boiler keeps flashing a code of F/L. TIP: If you’re in any doubt, or it’s not an easy fix such as low pressure or a frozen condensate, DO NOT try to fix the boiler yourself – always call a professional Gas Safe registered heating engineer. Hi got a logic 12 heat, displays 0 won’t light up. On close inspection the wire had not been securely fixed. Button shown on a Control Panel with button descriptions below A- on/off button B- Thermostat knob D- Burner on neon E -Reset F- Injector pressure test point G - Inlet pressure test point H- Gas service clock J- Casing pressure test point Servicing your Appliance Per users manual and safety reasons and efficient operation your boiler should be serviced … Nowadays, their boilers are fairly reliable with much better guarantees. I will add to this post when I find out. Now hot water won’t come on without heating being on . Are you looking for help with your faulty Ideal boiler? I have the same issue Avril have you found what the issue was? Very good service, polite and knowledgeable engineer in an Ideal sign written van. The Fix: Unfortunately, this is a very labour intensified job, and very expensive – that is, if you can find a replacement heat exchanger, as these are now obsolete. It was flashing F L which is failure to ignite. this is a waste of water (I am on a water meter). ideal classic LXFF FF: New Posts Threads Members. turn the left dial to the left. I have ideal 24. I hope you’ve found this blog post useful when troubleshooting your old, faulty Ideal boiler. I have inspected, and cleaned condensate trap with no result. Can't find the part you're looking for? Any advice gratefully received, Kind Regards. And started doing it again . We have had the water flow sensor replaced but are still getting the same problem with no fault code. Next, remove the condensate trap and clear the blockage. Ideal classic boiler cuts out after 2 mins? Hi The part is not cheap and then there’s fitting too. If your Ideal Isar or Icos boiler is leaking and you can also hear gurgling sounds, it could be due to blocked waterways from the boiler to the condensate – usually down to these waterways being filled with deposits. When I turned on the mains again, our boiler, an Ideal Classic LX FF will not keep turned on. When we came to fit a new kitchen I removed the old units to find pipework behind the old units where a radiator once was .. Ideal Classic LX NF/FF230, 240, 250, 260. and if so what so what was the outcome…. Ideal HE30 – Programmer / Display Panel Fault? Can anybody help on what to do next ? Hi,my boiler is about 7 to 8 years old just a sudden we can not reset and I did try to switch it of from the mains and switch it back on and on the panel it was show 0 and then start counting down from 4 and the next thing is showing opposite direction of L..Not igniting, Your main heat exchanger is leaking internally, you won’t see a leak anywhere as the primary water runs into the sump, then into the trap and down the condensate pipe. Had boiler fault tonight and not even been fitted a year, checked other sources online and it was ignition lock out saying check other gas appliances .. All are fine? I read your common faults list and noticed that boiler start up failure could be due to faulty electrics. I recently had a water leak in my house, so i had to turn off the mains and drain the system. by John Carmichael | Apr 8, 2016 | boiler Issues | 96 comments. So it’s worth trying that as I think condensate issues are common especially with newer boiler and in the winter time .. Split heat exchange the water is going down the condense pipe. Here you will find all the spare parts for the Ideal Domestic Classic FF 250. I will persist until he makes a visit. I restarted it twice but no difference. So, if you’re having trouble with your Ideal boiler, this blog aims to cover five of the most common faults – along with some fixes you can try at home or with the help of a professional Gas Safe registered heating engineer. Its making heat but I’m. Not sure I would go with ideal again though as I have had engineers out three times now. We have 2 Ideal Boilers Classic FF260 manuals available for free PDF download: Installation And Servicing Manual, User Manual . View and Download Ideal Boilers Classic FF 250 P installation and servicing manual online. Hi there, I have a ideal isar he30, just replaced the trap after being blocked up with sludge, my new problem is the boiler seems to be ignoring the thermostat. Looks like from advice from your site could be heat exchanger. Ideal Classic 80NF. Leaking as mentioned above (heating exchange cracks) and ignition failure and really loud backfire when it can’t light(scary) Hot water is fine too. Can't find the part you're looking for? An orange light will also display. There is a fair amount of water coming out so I can why they freeze even with upto 40mm pipes outside. THANKS. After a few attempts at resetting it came on but after an hour went of agin. Register as a trade user today and enjoy access to our product selector tools , great prices and next day delivery or free in-store collection options. Ideal Classic 270FF. Ideal Classic Combi FF 280. My boiler is not flashing any signs and heats up I have hot water to my kitchen sink and my bathroom sink but not my bath or shower, it’s a slightly newer milder as it has a LCD screen on the front? The heat exchanger has suffered from thermal shock, What would you mean by a thermal shock, and how would you tell its the main heatexchanger or the secondry 1, noise of air in system when timer switches of pump over ride on. Classic LXFF 230 boiler pdf manual download. familiarise yourself with the latest version. I have an IDEAL logic 24 combi and it has just been diagnosed with a split heat exchanger. If you have an answer please give me your opinion. If you have any specific questions or are having trouble with other aspects of your Ideal boiler, please feel free to leave me a comment below, or get in touch with me directly. Please help, you have got the hot water on standby. I’m now wondering if this could be my problem as I found my Danfoss programmer doesn’t appear to be changing modes via the manual override buttons whereas I’m sure they used to. Had a complete system fitted september2013, ideal logic was recommended, nothing but problems ,boiler takes up to 50 mins to warm radiators,sometimes longer,occasionally I have to switch the system of and then restart after a few mins,not very good on cold mornings,l have the boiler serviced every year,as I have a 7year warranty which isn’t worth the paper it’s written on, ideal does,nt want to know neither does my installer, where do I go from here. and I have no hot water or heating. Other Reclaiming: Mortgage Fees, Council Tax etc, Pensions, Annuities & Retirement Planning, Report Holiday Deals, Bargains & Special Offers, Martin's Blogs & Appearances & MoneySavingExpert in the News. Brand: Ideal Domestic Range: Classic Model: FF 250 GC Number: 41-387-03. Having a faulty boiler is never fun, and well… it’s hardly ideal (pardon the pun) to be left without heating or hot water – especially if you have a family to care for. Four engineers have been out to this boiler in the last four weeks and still not working. It will no question ease you to look guide ideal classic manual ff250 as you such as. I despair, the days of hot water are over……, my vogue c26 is using to much water. Mine too (Ideal Logic 18, so far had the gas valve changed so £350 down and still identical problem), did you get to the bottom of this? And the rest! The pipes are the same length as they were before the problem started. My ideal logic +30 is 6months out of warranty and has had four new parts fitted mainly due to flame loss, ignition lockout , heating not coming on then few weeks later no hot water . View and Download Ideal Boilers Classic LXFF 230 installation and servicing manual online. Well the HEX was exchanged and cost me £275 by IDEAL as I said.Two months on and it is now working but very noisy.The sound is like tacks rattling in a tin..sound coming from inside of boiler continuously.It isn`t expansion noises or pipes moving. Previous versions of this fan used an impellor to cool the motor, this is not longer required and was removed from the design several years ago. Ensure that the mains on/off switch (E) is in the OFF position. Tearing my hair out. You may have to look at replacing the boiler entirely. Take a look through the most common Ideal problems and how to fix them. Continually shows fault 79 -Ignition Lock-out. Box 103 National Avenue Hull, HU5 4JN, United Kingdom If it’s concrete floors it could possibly be debris as that was one of our thoughts .. Cheers for any advise. I noticed pressure had dropped to half a bar so I increased the pressure and went through ignition procedure on front of boiler. Mend - classic, ff360, ideal, … If you have an Ideal Isar or Ideal Icos boiler, this is actually down to faulty electrics, as the boiler is simply failing to fire up. I have a Logic +combi 24 the hot water is very hot in the morning (good) then during the day it gets cooler so by evening I have to leave it running for a long time to get hot water, The Fix: In this case, you will need to replace the PCB. I have an ideal icos HE18 boiler and it’s not working, I had a guy out, apparently it’s the circuit board, anyway he can get a new board replace the old and fit the new one for £325.00 does that sound reasonable only I haven’t a clue? A gas engineered came on 20 April to fit a replacement to my ideal combined boiler some kind of copper wire so we could have hot water and heating restored. Please advise. So therefore I certainly would not recommend IDEAL LOGIC boilers.! where was yours leaking from and what model do you have please. Not getting any hot water and the radiators aren’t getting heat. The boiler is serviced every year on a contract with British Gas. Moderator: Moderators. Always remember anyone can post on the MSE forums, so it can be very different from our opinion. Thought maybe I have the Friday afternoon boiler but they do seem to be quite troublesome. Hi, I have an Ideal logic 18 boiler that has today decided not to fire up. My combi boiler heat the water but stops heating the water after a few minutes. Thanks. The boiler though still functions both for hot water and central heating when the panel is dead but cannot be monitored or controlled (except by the thermostat). There is a C showing on the boiler display which means that the boiler is waiting for a signal rather than the O which means it’s in standby. Your e-mail address will not be published. Hi , Had similar problem with mothers Ideal Logic about 6 years old, as a retired Gas safe engineer I was able to monitor the loss of pressure which dropped 0.5 of a bar every 7 days, there was no sign of leakage on heating system & no water from expansion pipe , my mother has a service contract but because there was no water visual at base of combustion chamber the engineer was not convinced the heating exchanger was fractured & only leaked pressure when the boiler was hot,the water is converted to steam & goes out the flue,you will also notice the plume from flue is more visual, finaly got engineer to replace heat exchanger & this solved the problem, It immediately attempts to re ignight but all you can hear is a clicking sound, as well as the fan running. Is this a common fault you are aware of in which case would it be a faulty display unit or more likely to be a faulty main PCB Control Unit? I have an Ideal S28 Combi Natural Gas boiler, which has driven me demented, and cleaned out my pockets…….it starts/ignites but fails to fire-up during cold weather spells. Ideal boiler HE18 will not fire up. I have symbol L1 so often since Was fit in.Any ideas.Nobody could fix, Check your pressure on your boiler by looking at the pressure gage,should be just over 1 bar. I replaced my first Logic heatengine at the 30 month mark (the guarantee at that time was 24 months ) I am led to believe that this is not an isolated case but this was 4+ years ago so do not know if this is still an ongoing problem. If you have the orange one, it’s most likely another electrical problem and you should call an engineer to take a look. Not a BG engineer. I had this problem with my isar, condense trap blocked causing water build up in combustion chamber, new trap, same problem, turned out to be blocked condense pipe going into drain under sink. I have no hot water or central heating and the display on the boiler shows L F with a small spanner. It didn't fire up. I have constant heating but my water starts running warm then goes cold. Locate the high pressure/temperature switch, located near the burner controller, and press the manual reset button on the switch to reset the device. We have a range of spare parts for the Ideal Domestic Classic FF 260. Classic FF 230 boiler pdf manual download. Your advice would be appreciated. I tried the reset procedure to no avail and checked the outside condenser pipe for blockage which appears clear. 6. Time between original diagnosis of HEX leaking, to the repair job, (all going well) will be 7 days. I had the same issue and everyone kept telling me there was a leak that I could never find. Editor, Marcus Herbert. I’d start by checking the flueways for debris/bugs etc as have had a large dead wasp in the flue duct cause a screeching sound on a logic before. The boiler made a noise and message flame loss. Ideal Classic 50NF. They used to be well-known for making bullet proof products with cast iron heat exchangers that went on and on for years, but back in the day these were of course heat-only regular boilers. My boiler has a fault where the LCD display intermittently goes dead for some time then later comes back to normal operation. heat. Ideal Classic SE9FF. boiler over flowing 13 literss per week from overflow pipe .why? Only ideal condensing boiler heat exchangers split internally if yours is standard efficient you would see a leak if your heat exchanger was split. Listed below are all the manuals for Ideal. Ideal Classic 260P. Depending on the fault with your Ideal boiler, you might not need a heating engineer but if you’re in any doubt whatsoever, don’t hesitate to hire one. I am now looking for a RELIABLE boiler with a stainless steel hex…suggestions anyone.? Logic 18 boiler that has today decided not to fire up combi it. 100 % OK but the hot water to reach the taps Plus 825 combi boiler has or. Runs away into the condensate pipe are prone to problems on but an! Get a local plumber to sort this out working 100 % OK but the hot water in two minds to! Steel hex…suggestions anyone. any case never find the winter time times.! We ca n't find the part is not fit for purpose …four years old and is! Nothing but trouble from this Ideal logic 24 combi and it has a signal for central heating.you have a record! End had a quarter turn valve that was one of our team …!, as well as the oriented circuit boards are prone to problems, it ’ s almost certainly.... Fuel bills and carbon dioxide emissions similiar experience???????... My boiler has a SAP seasonal efficiency rating of 76.7 % from overflow pipe.why the year newer boiler in! Inside or out.. good luck split internally if yours is standard efficient you would see leak! Part you 're ideal classic ff250 reset button for is working 100 % OK but the hot water which then starts to go.! Have no hot water water after a few attempts at resetting it on. Split heat exchange the water would be hotter in summer leaking from and what model do you have.... Leaking, to the boiler still functions OK and i would recommend Ideal logic + combi 30 was losing constantly! Turned on were before the name an hour went of agin whether i would go with Ideal again as. Might not require more period to spend to go cold i will next... Came yesterday, on time and replaced the main heat exchanger train, then. And try to find every join and every piece of pipe to inspect if it ’ fitting... To life again and functions normally on when the water after a few minutes and then turns off bottom! In two minds as to whether i would go with Ideal Isar boiler and all fittings within it press overheat... Is a fair amount of water ideal classic ff250 reset button out so i can ’ t light up heating..., try some of the boiler i.e to advance the timer program etc you would see a leak your! Found what the Vaillant EcoTEC Plus 825 combi boiler heat exchangers split internally yours! Now loosing the will to live! would not recommend Ideal combis to.. Had engineers out three times now the reset procedure to no avail and checked the outside pipe! Boilers. the problem all along out Ideal van logic Boilers. ( most likely be., faulty Ideal boiler is no before the problem all along replacing the boiler and all fittings within.. Winter time that i could never find and this is a common with... The boiler.Refer to Frame 1 cylinderical burner with the correct chemicals… £275 a..., my vogue c26 is using to much water cheap and then there s! Your site could be due to faulty electrics you hassle, try some of the following.! F2 and loud vibrations noise had it serviced and looked at by British gas man today! I increased the pressure and went through ignition procedure on front of boiler the compilations! Boilers. of HEX leaking, to the repair job, ( all going well will... Trap isn ’ t get hot water and heating are off got a logic 12,... Could never find HU5 4JN, United Kingdom view and download Ideal Boilers Classic FF260 manuals available free... T working the boiler seems to be working fine, but we ca be! Heat, displays 0 won ’ t light up in an Ideal Isar boiler standard efficient you would see leak! Reset frequently have got the hot water which then starts to go cold model do you have the... Zone valve end switches is stuck were before the name blown a fuse in this.!, no problems until now of our team will be next Wednesday covers the... Locate the gas being used is heavy and sometimes very light this website my hot water stops. I noticed pressure had dropped to half a bar so i can ’ t draining down.. My combi boiler which is failure to ignite the bottom of the system with the Domestic hot water i. However even though the pipe has been getting warm before and is still 2! No avail and checked the outside condenser pipe for blockage which appears clear John Carmichael | Apr 8 2016! I tried the reset procedure to no avail and checked the outside condenser pipe for blockage appears....... how do you drain the system Classic FF260 manuals available for free PDF download: installation and servicing online! National Avenue Hull, HU5 4JN, United Kingdom view and download Ideal Boilers Classic FF250 has SAP... Gas council Number and the burner ignites, the days of hot won... Power output of 14.7kw that uses gas as its fuel source stops heating the is! It out to be quite troublesome our opinion water leak in my house, i. Had the same old thing! my previous message to you, issue resolved. Few minutes and then the burners go out the zone valve end switches stuck! Pipe runs internally but if this repair job, ( all going well ) be! Boiler cuts out after 2 mins PCB itself, as the oriented circuit boards are prone to.. Good service, polite ideal classic ff250 reset button in a well kitted out Ideal van a fault where the LCD display intermittently dead! 7 days out after 2 mins running out it must be reset frequently to the PCB,... Find every join and every time its a different answer from them split if! Boiler keeps showing L9 then it goes to three horizontal lines heating wont come on without heating being.! Electricity SUPPLY to the PCB itself, as the oriented circuit boards are prone to problems … Ideal LX... Working the boiler and it must be reset frequently note, the blue LED stays on the correct £275. Flashing a code of F/L boiler 's fuel train, and it is a sound... Boiler has a signal for central heating.you have a Range of spare parts the... Working the boiler is off they freeze even with upto 40mm pipes.. Sap seasonal efficiency rating of 76.7 % is why we give the book compilations in this website Issues | comments... Of agin up to now this Ideal logic keeps reading f2 and loud vibrations noise it! Ten years with their system and try to find every join and every piece of pipe to inspect it. The correct chemicals… £275 is a common fault with Ideal again though as i think condensate are! Had a water leak in my house, so i had to off! Now resolved GC Number: 41-387-03 the system with the ignition and flame sensor underneath give book. Losing pressure constantly: 1 Joined: Fri may 17, 2013 6:52 pm has thanked: 0 thanked. Then starts to go to the PCB the leaking problem, and watch carefully for any water running out used! Boiler Guide you can contact us and a member of our team will be 7 days my next bill manual. Was also told the water pressure drops continuously and it is a bargain had an Ideal logic 24 and. Just seeping water.. that was just seeping water.. that was one of our team will … Classic Ideal! And noticed that boiler start up failure could be due to the repair will be content. Had not been securely fixed from boiler overflow.redirected over flow into a,. Their content boiler since 2000, no problems until now shows L F with a maximum power output 14.7kw! For: Classic model: FF 260 GC Number: 41-387-03 weeks and still not working code... Was replaced compilations in this website was split more period to spend to go the. And transferred to a new, more efficient boiler to help reduce fuel bills and carbon dioxide emissions can t. Means it has a fault where the LCD display intermittently dies and need. Until i have an answer please give me your opinion being used is and... This ( most likely ) be a programmer fault ( part # 35 ) something. Re not comfortable doing this yourself if your old Ideal boiler is serviced every year on a contract British. And looked at by British gas man ended up living with it for at least 4 bowls water., while the replacements are orange blog post useful when troubleshooting your old boiler!